Unified Network Storage

Unified Network Storage

  • Brand:: UniView
  • Product Code: VX3000-V2
  • Availability: In Stock

Please log in for price


Unified Network Storage

  • • Dual/Single Controller
    • 24/48/60 SATA HDDs,up to 18TB for each HDD
    • 4×48/2×48Gbps Mini SAS HD ports
    • Support iSCSI
    • Support JBOD and RAID 0,1,10, 5, 50,6
  • High Available

    * Failover

    When the controller detects the fault of the other controller, it automatically takes over the works of fault controller.

    * Mirror write cache

    Between controllers, write caches switch data by ×16 PCIe3.0, to ensure the integrity of the user data after failover

    * Dynamic migration of virtual IP

    When the controller takes over the fault controller, the virtual IP of fault controller will migrate to the controller to ensure the continuity of the service

    Intelligent RAID Engine (ISET)

    * Convenient RAID application

    The RAID can be used immediately after being created. The system automatically initializes at the background.

    * Free from the impact of abnormal RAID status

    The performance of storage devices usually deteriorates in the case of RAID degradation. The Intelligent RAID Engine technology can be a shield against the impact of abnormal RAID status on services to ensure the normal operation of front-end monitoring services.

    * Free from the influence of concurrent reading/writing

    The IOPS multiplies when concurrent reading and writing occurs on a disk. The Intelligent RAID Engine technology can be a shield against the impact of video recording and playback to ensure the normal operation of front-end services.

    * Cache algorithms for videos

    Optimized read/write cache management algorithm, greatly improving access performance and extending the lifespan of HDDs.

    * SSD Cache

    The use of SSD Cache can be greatly improving access performance of hot data

    * Dynamic adjustment of reconstruction speed

    The system adjusts the reconstruction speed automatically based on the system conditions to reduce the impact of RAID reconstruction on services and to improve the effective utilization of system resources.

    Super Error Correction (SEC)

    * Automatic disk inspection and repair

    The unique hard disk fault-tolerant processing algorithm ensures service continuity even when multiple disk errors exist in the array. Fault sectors can also be automatically repaired.

    * Fast disk reconstruction

    Data can be copied to a hot spare disk within a short period. This substantially reduces the read I/O of disk, speeds up the reconstruction, and avoids data loss.

    * RAID superblock backup

    Array composition is not affected when data in a certain sector cannot be read. In addition, damaged data can be repaired by using the backup sector to improve array reliability.

    Data Protection

    * Data safe box

    Online embedded UPS protection and data safe box are provided to ensure secure writing of cache data into data safe box at unexpected power-off without data loss.

    * Disk pre-copying

    Pre-detection of failure is implemented to transfer data from risky disk to the hot spare disk.

    * Disk protection

    Once a disk error is detected, the disk repair process would automatically start. Data in the failed disk is recalculated from other disk in the array to remap the bad blocks of disk.

    * Link protection

     ink aggregation and dynamic failover ensure the read/write bandwidth without affecting the availability of data channels.

    Three Dimensional Linear Expansion

    * Seamless expansion based on LUN resources

    * 4-port 4*12 Gbps Mini SAS HD interfaces for back-end expansion.

    High-Quality Hardware Design

    * High density

    The innovative enclosure with mm depth and 4U height that holds up to 60disks, is space-saving and applicable to the standard rack-mounted scenarios.

    * Carrier-class applications with high availability

    The application of Intel 64-bit server platform architecture, 64-bit multi-core processor, ECC DDR4 memory, and 64-bit storage OS ensure excellent service continuity by providing stable and reliable data access. The system availability reaches up to 99.999%.

    * Watchdog

    The system would be forced into the security mode in case of a failure. High-speed cache data is stored in the data safe box. Storage media in the data safe box can roam to the new system together with the array disk. The system can be recovered securely and conveniently.

    * Dual BIOS

    When the active BIOS fails to start, the system automatically detects the failure and switches to the standby BIOS. This ensures reliable system startup and BIOS update.

    * Redundant power supplies

    The hot-swappable power supply is designed in redundancy and load balancing mode. Automatic power switching in case of failure and online replacement of failed power supply are supported.

    * Overload protection

    The mechanism of hardware overload protection is provided. When the temperature reaches the protection threshold, the system automatically turns off to protect the disk data.

    * When CPU and memory malfunction or reach the protection threshold, the system automatically sends alarm messages through mails, short messages, and SNMP Trap.

    * Power protection

    Disk powered on sequentially during system startup, protection from impulse current.

    * Multistage fan speed and energy saving

    Fans with multistage speed are configured in the hot-swappable frame in redundancy mode. System power consumption can be balanced intelligently with heat dissipation calculation to ensure low power consumption and stable operation of the system.

    * Convenient maintenance

    Functions as indicator alarm, mail alarm, beep alarm, SNMP Trap alarm and SMS alarm are supported.

    Automatic startup after unexpected power-off, and timed startup and shutdown are also available.

    The environmental monitoring function allows the monitoring of the utilization of network interface and CPU, the querying of the access of LUN and RAID, as well as the management of device voltage and temperature. In this way, administrators can comprehensively inspect system operation condition and reasonably allocate resources to maximize the device performance.

    Green Technology and Energy Conservation

    * Selected power supplies with high PF and conversion efficiency

    * Intel CPU with cutting-edge process technology and advanced architecture

    * Particularly selected chips with low power consumption for service model of video surveillance

    * Unique simplified design of board

    Reduced component type and quantity, under the affirmatory premise of the function, performance and reliability

    * Multistage fan speed

    Several temperature sensors are configured and built inside to intelligently control the fan speed.

    * Hibernation for unoccupied disks

    * Intelligent cache design

    Reasonably sort and buffer the read/write data by intelligent algorithm reduce the disk read/write times,and reduce the hard disk power consumption.

    ItemVX3024-V2VX3048-V2VX3060-V2VX3060-V2@S
    controller21
    performanceVideo Mode512-channel(1024Mbps) recording,
    512-channel(1024Mbps) forwording,
    51-channel(102Mbps)playback
    IPSAN Mode512-channel(1024Mbps) recording,
    51-channel(102Mbps)playback
    Storage controllerIntel 64-bit multi-core processor
    Memory16GB, up to 128 GB8GB, up to 64 GB
    Front-end Service Interface10-port 10/100/1000 Mbps Ethernet interface5-port 10/100/1000 Mbps Ethernet interface
    4-port 10/100/1000 Mbps Ethernet interface module(optional)
    2-port 10 GE SFP+ interface module(optional)
    4-port 10 GE SFP+ interface module(optional)
    Back-end Expansion Interface4-port 4*12 Gbps Mini SAS HD2-port 4*12 Gbps Mini SAS HD
    Host ConnectionUp to 1024
    HDD24 SATA/SAS/NL SAS interfaces48 SATA/SAS/NL SAS interfaces60 SATA/SAS/NL SAS interfaces
    Disk Capacity1 TB, 2 TB, 3 TB, 4 TB , 5 TB, 6 TB, 8 TB , 10 TB, 12 TB, 14 TB, 16TB, 18TB
    RAIDJBOD and RAID 0,1,10, 5, 50,6
    Dedicated hot-spare disk and global hot-spare disk
    Maximum Number of Logic Resources1024
    Protocol SupportediSCSI
    Alarm FeatureIndicator alarm, beep alarm, mail alarm, SNMP Trap alarm, and short message alarm
    Operating SystemWindows and Linux
    Power Supply2default(1+1)3default(2+1)2default, 1 optional
    Batteryat least 21
    Dimension(H ×W×D)Controller enclosure: 175mm×482mm×589mmController enclosure: 178mm×482mm×801mm
    Note:for standard cabinet with 1000mm depth or above
    Controller enclosure: 178mm×482mm×981mm
    Note:for cabinet with 1200mm depth or above
    Power ConsumptionController enclosure :<550W (fully configured)Controller enclosure :< 700W (fully configured)Controller enclosure :< 1000W (fully configured)Controller enclosure :< 900W (fully configured)
    Power Supply100 V – 127 V/ 200 V – 240 V AC, 60 Hz/50 Hz
    WeightController enclosure :Fully configured:< 45kgController enclosure :Fully configured:< 68 kgController enclosure :Fully configured:< 96kgController enclosure :Fully configured:< 93kg
    Authentication certificateCE, FCC, UL
    Operating temperature5 °C~40°C / 41 °F ~ 104 °F,(10°C~ 35°C / 50 °F ~ 95°F Recommended)

Tags: network storage unified, network, storage